-70 Degree Dew Point 60 Nm3/H PSA Nitrogen Generator For Replacement Of The Gas Environment

Podstawowe informacje
Place of Origin: Jiangyin,Jiangsu,China
Nazwa handlowa: True
Orzecznictwo: ISO,CE
Model Number: TY
Minimum Order Quantity: 1set
Cena: Negotiation
Packaging Details: wooden case packing
Delivery Time: 10 working days
Supply Ability: 20 sets per month
Dew point:: -70 degree Usage:: gas environment replacement
Voltage:: 380V/220V/50HZ Purity::: 99.9%
Color:: Blue,White
High Light:

nitrogen psa generator

,

psa nitrogen gas generator

-70 degree dew point 60Nm3/h purity 99.9% PSA nitrogen generator for replacement of the gas environment
 

 

Technological Advantages

Close Air Handling System;

Special Low Shunt and Non-Wear Soft Clamping Device.

Long-life Pneumatic Valve

Innovative Low Noise Silencer

Unique Touch Switch and Liquid Crystal Display

High Automation and Can be Unattended

Equipment Structure Compact and Reasonable

Produce Nitrogen Fast with Short Time

 

Now, nitrogen generator has been the necessary device of many companies. Many works know how to operate the machine but don’t know how to maintain it. Maintenance is important to any machine. Good maintenance can prolong the working life of the nitrogen generator effectively. Besides, proper usage is the key to prolong the working life of the machine.

Operational Procedure:

Close all power switches, including the nitrogen generator, nitrogen gas inlet valve and sampling valve. Wait to the end of the decompression. Adjust the oxygen analyzer to sampling and adjust the pressure of reducing valve to 1.0 bar. Adjust the sampling flow meter around 1. The sampling volume should not be too large, then start to detect the nitrogen purity.

Don't open the globe valve of the nitrogen generator until the pressure of the pressed air is over 0.7mpa. Observe the changes of the adsorption tower and the working condition of the pneumatic valve.

When the pressure of the regeneration tower equals zero, the pressure of the two adsorption tower should approaches to the half of original pressure.

Turn off the whole machine and the other parts of the machine. When the pressure of the two towers reaches around 0.6Mpa, observe whether the nitrogen machine works properly or not.

 

 

 

Jiangsu Tongyue Gas System Co.,ltd. established in 2011,specializes in the production of nitrogen generators, air compressors, oxygen and other gas processing equipment. The products are widely used in Oil and gas industry ,medicine, chemical industry, chemical fiber, metallurgy heat treatment, electronics, steel, coal, and other industries.

Our company has a number of patented technologies and intellectual property rights. Now we have 8 engineers,60 employees. We insists on using high-quality imported parts, and have established and improved production processes, quality control system, and after-sales service evaluation system, to provide best service to each customer.

Our businesses cover throughout the country, and we also exported our products to Southeast Asia, Europe ,Mid east and other overseas markets.

 
 

 
 
Technological Advantages

Close Air Handling System;

Special Low Shunt and Non-Wear Soft Clamping Device.

endif]>Long-life Pneumatic Valve

Innovative Low Noise Silencer

Unique Touch Switch and Liquid Crystal Display

endif]>High Automation and Can be Unattended

Equipment Structure Compact and Reasonable

Produce Nitrogen Fast in Short Time

 

 

 

 

Product Features
1. The nitrogen purity can be adjusted from 95%-99.99%. The nitrogen gas is dry and its dew point is low, these help to preserve the food.
2. The machine features excellent cost effectiveness and fast capital payoff.
3. Its exterior is concise and small, so is to be conveniently cleaned and meet the high cleanliness requirement of the food industry.
4. The product is made of high quality equipments and its skillfully process makes itself durable in use.
 
 
Food Grade Nitrogen Generator Operation Cautions

1. Regulate nitrogen production valve according to the air pressure. To ensure the machine in a good condition, don’t to raise the air flow.

2. The nitrogen gas valve opening should not be too large to ensure a best nitrogen purity.

3. The flow meter of Nitrogen analyzer should be adjusted to 0.5L/H.

4. The adjusted valve should not be turned or the nitrogen purity will be influenced.

5. The electric parts in the control cabinet and pneumatic pipe valve should not be touched randomly.

6. The operator should check the pressure gauge regularly.

7. Output pressure, flow indicator and nitrogen purity should correspond with the required valve. Once the problem happens, actions should be taken to solve.

8. Maintain the air compressor, air dryer and filters according to the technical requirements to ensure the air quality(The air source should be oil-freed)

9. Air compressor, air dryer should be maintained at least once a year. And the wear parts should be replaced and maintained accord to the equipment maintenance.

10. The carbon molecular sieve should be checked at least once a year for a certain degree of wear of the carbon molecular sieve.

11. To fill in the daily record form completely.

 
Manufactured capacity:
 

Factory name/address Manufactured item annual production capacity

 
Jiangsu Tongyue Gas system Co., Ltd
2030 Zhengcheng Road, Xishiqiao Town, Jiangyin City

pressure swing adsorption nitrogen geneerator 350 sets/year

 
Ammonia decomposition hydrogen production equipment

300 sets/year

 
methanol reforming hydrogen

50 sets/year
other gas equipment 90 sets/year
     

 
Service Commitment:
1. When receiving debugging information from our customers in the debug phase, we will arrive to the site in 48 hours if the debugging condition limited.

2. When the machine in operation, if you have any questions, please turn to our after-sales for help: 1381217593. We will provide you with reasonable suggestions and help them to solve the problems.

3. To the customers who need to change the accessories, we will send to you as soon as possible.

4. Any operational problems with the machine, we will arrive the site in 24 hours.

5. Any dissatisfaction with our after-sale services, please call our complains hotline:0510-86625066 

-70 Degree Dew Point 60 Nm3/H PSA Nitrogen Generator For Replacement Of The Gas Environment 0
 

Szczegóły kontaktu
Ms.Vera

Numer telefonu : +8613961615106

WhatsApp : +8613961615106